15
MINIMUM CLEARANCE TO COMBUSTIBLES
Maintain these minimum clearances to combustibles from fireplace and vent surfaces:
Fireplace framing:-0” to
-0” to rear
-29 1/2” recessed depth
-84” from bottom of unit to enclosure top
-2” to top, sides, and bottom of vent pipe*
-84” from bottom of unit to ceiling
Non- Combustible Fireplace finishing:Front - 5 1/2” to sides of fi replace opening
-23 3/4” to top of fi replace opening * See Venting Section
It is recommended that the walls of the fireplace enclosure be finished. This would ensure that clearance to combustibles is maintained within the cavity.
FIGURE 29 | ! | WARNING |
|
Use only
WOOD OR DRYWALL.
| 23 3/4" |
|
| 73 | 1/4" |
5 1/2" | 5 1/2" |
|
| 60 3/4" |
|
!WARNING
Facing and/or finishing material must never overhang into the fireplace opening.