ROOM THERMOSTAT

23

ROOM THERMOSTAT

The remote transmitter can operate as a room thermostat. The thermostat can be set to a desired temperature to control the comfort level in the room.

1.Press the Thermostat Key. The LCD display on the Transmitter will show that the room is FIGURE 52 “ON” and the set temperature is now displayed.

2.To adjust the set temperature, press the Up/Down Arrow Keys until the desired set tem-

perature is displayed on the LCD screen of the Transmitter.

SMART THERMOSTAT

The Smart Thermostat function adjusts the fl ame height according to the difference between the set temperature and the actual room temperatures. As the room temperature gets closer to the set point the Smart Function will automatically adjust the fl ame down.

1.Press the thermostat key unit the word “SMART” appears to the right of the temperature bulb graph-

ic.

2.To adjust the set temperature, press the Up/Down arrow keys until the desired set temperature is dis- played on the LCD screen at the Transmitter.

FIGURE 53

FLAME HEIGHT

The remote control has six (6) fl ame levels. With the system on and the

ame level at the maximum, press the Down Arrow Key once and it will reduce the fl ame height by one step until the fl ame is turned off.

The Up Arrow Key will increase the fl ame height each time it is pressed. If the Up Arrow Key is pressed while the system is on but the fl ame is off, the flame will come on the high position. A single “beep” will confirm reception of the command.

FIGURE 54

FIGURE 55

Flame OFF

Flame at level 1

FIGURE 56

FIGURE 57

Flame at level fi ve

Flame at “HI” level six

FAN SPEED

If the appliance is equipped with a hot air circulating fan, the speed of the fan can be controlled by the remote system. The fan speed can be adjusted through six (6) speeds.

1.Use the Mode key to guide you to the fan control icon.

2.Use the Up/Down Arrow keys to turn ON/OFF or adjust the fan speed.

A single “beep” will confi rm reception of the command.

FIGURE 58

FIGURE 59

Blower Off

Blower at HI