Napoleon Fireplaces BGD90PT Electrical Connection, Minimum Mantel And Enclosure Clearances, a-b

Models: BGD90PT BGD90NT

1 32
Download 32 pages 38.75 Kb
Page 16
Image 16
MINIMUM MANTEL AND ENCLOSURE CLEARANCES

16

MINIMUM MANTEL AND ENCLOSURE CLEARANCES

IMPORTANT:

The FIGURE 31a-bELECTRICAL CONNECTIONHARD WIRING CONNECTION requires a minimum inside enclosure height of 84” measured from the bottom of the fi replace.

For temperature requirements, this area must be left unobstructed.

It is recommended that the enclosure be ventilated at the top and bottom to circulate the hot air with 2, 40” square openings.

FIGURE 30

Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clearance needed.

 

 

FIGURE 31a-b

 

 

9

 

 

 

 

 

 

M H

8

 

 

 

 

 

 

A E

7

 

 

 

 

 

 

N I

6

 

 

 

 

 

 

T G

5

 

 

 

 

 

 

E H

4

 

 

 

 

 

 

L T

3

 

 

 

 

 

 

 

0

1

2

3 4

5

6

7

MANTEL DEPTH

* See Venting Section

**Within the fireplace enclosure a 9” clearance between the vertical vent run and the combustible materials on the front facing of the enclosure is required. Similarly, a 5” clearance to combustible materials from the top of the horizontal vent run is required. All other clearances within the enclosure, including where the vent pipe exits the enclosure are subject to 2” for horizontal and 1” for vertical.

ELECTRICAL CONNECTION

Do NOT use the fireplace if any part has been under water.

Call a qualified service technician IMMEDIATELY to have the fire- place inspected for damage to the electrical circuit.

If access to the control area is necessary BEFORE INSTALLATION, remove the access panel. Located along the right side of firebox.

The access panel must be re-installed before operating the unit.

HARD WIRING CONNECTION

It is necessary to hard wire this fireplace.

Permanently framing the fireplace with an enclosure, requires the fire- place junction box to be hard wired.

This fireplace must be electrically connected and grounded in accor- dance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/ NFPA 70-1996 NATIONAL ELECTRICAL CODE in the United States.

SCHEMATIC

 

BLOWER

ON

 

REMOTE

 

OFF

REMOTE

ON

OFF

Receiver Wall Mount

Receiver Hearth Mount

Receiver

12Pin Connector

RECEIVER

110V OUT FAN AUX OU

T

 

Night Lights

Fan Control Module (FCM)

 

 

 

 

 

 

 

 

FCM-COM

TH

FIGURE 32

TP

Red

Black

OUT

White Green

Modulating 820

 

TPTH

MOTOR

W415-0580 / C / 04.07.08

Page 16
Image 16
Napoleon Fireplaces BGD90PT Electrical Connection, Minimum Mantel And Enclosure Clearances, Hard Wiring Connection, a-b