25
OPERATING INSTRUCTIONS
When lit for the fi rst time, the fireplace will emit a slight odor for a few hours. This is a normal temporary condition caused by the curing of the paints and lubricants used in the manufacturing process and will not occur again. Simply open a window to suffi ciently ventilate the room.
After extended periods of
Purge all gas lines with the glass door of the fireplace removed. Assure that a continuous gas flow is at the burner before installing the door.
FOR YOUR SAFETY READ BEFORE
LIGHTING:
A.This fi replace is equipped with a pilot which must be lit by hand while following these instructions exactly.
B.Before operating smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor.
C.Use only your hand to turn the gas control knob / manual
D.Do not use this fi replace if any part has been under water. Immediately call a qualifi ed service technician to inspect the fi replace and replace any part of the control system and any gas control which has been under water.
WHAT TO DO IF YOU SMELL GAS
•Do not touch any electric switch.
•Do not use any phone in your building.
•If you cannot reach your gas supplier, call the fi re department.
• Turn off all gas to the fi replace. | FIGURE 65 | |||
• Do not try to light any appliance. |
|
|
|
|
• Immediately call your gas supplier |
| L |
| |
|
|
| ||
from a neighbor’s phone. Follow the | I | O | ||
P |
|
| T |
gas supplier’s instructions.
WARNING: if you do not follow these | F | O |
F | N | |
instructions exactly, a fi re or explosion may | O |
result causing property damage, personal |
| |
injury or loss of life. Initial lighting of the pilot |
| |
and main burners must be done with the | GAS KNOB | |
glass door off. | ||
|
LIGHTING INSTRUCTIONS
Do not connect valve or wall switch to electricity. See installation instructions.
When lighting and
1.STOP! Read the safety information on the operating label.
2.Turn off all electric power to the fi replace.
3.Turn the gas knob clockwise to off.
4.Wait 5 minutes to clear out any gas. If you smell gas, including near the fl oor, STOP! Follow “B” on the operating label. If you don’t smell gas, go to the next step.
5.If the fi replace is equipped with a fl ame adjustment valve, turn clockwise to off.
6.Find pilot located in front of the back log on the right.
7.Turn gas knob
8.This unit is equipped with an
9.With pilot lit, push and turn gas knob
wise to on.
10.If equipped with fl ame adjustment valve, turn knob to high.
11.If equipped with remote
12.Turn on all electric power to the fi replace.
FIGURE 66
TO TURN OFF GAS
1.Turn off all electric power to the fi replace if service is to be performed.
2.For a complete
slightly and turn clockwise to off. Do not force.
3.For a temporary
Press and turn the gas knob clockwise to pilot.