Napoleon Fireplaces BGNV40-N, BGNV40-P Gas Installation, at the burner before closing the door

Models: BGNV40-N BGNV40-P

1 28
Download 28 pages 8.45 Kb
Page 13
Image 13
GAS INSTALLATION

13

GAS INSTALLATION

Proceed once the vent installation is complete.

1.Move the fireplace into position and secure using the nailing tabs and/or secure to the floor through the 1/4"ø holes located at either end of the base.

2.Route a 3/8" N.P.T. black iron gas line, 1/2" type-L cop- per tubing or equivalent to the fireplace.

3.For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient lo- cation. Route 2-strand (solid core) millivolt wire through the electrical hole located at the bottom left side of the unit. The recommended maximum lead length depends on wire size:

WIRE SIZE

MAX. LENGTH

14gauge

100 feet

16gauge

60 feet

18gauge

40 feet

Attach the one lead to terminal 3 (located on the gas valve) and the other lead to the vent safety switch wire ( located loose in the valve compartment). See FIGURE 3.

Do not connect either the wall switch, thermostat or gas valve to electricity (110 volts).

FIGURE21

1

 

 

 

 

2

 

OL

 

 

 

 

O

F

 

 

 

 

N

O

 

 

 

HI

F

 

 

 

 

IP

 

 

 

 

 

 

 

3

 

 

TOL

 

 

P

 

 

 

 

 

TOLI

 

 

4.Install rigid black pipe, 1/2" type-L copper tubing or, if local codes permit, a 3/8" flex connector and shutoff valve to the gas line and the fireplace gas valve. Seal and tighten securely. An adapter fitting is required between the gas valve and the copper tubing or flex connector. DO NOT KINK

FLEXIBLE CONNECTOR. FIGURE 6.

5.Check for gas leaks by brushing on a soap and water solution. Do not use open flame.

FIGURE22

6.Mark the appropriate boxes on the rating plate label to indicate the model type.

Purge all gas lines with the glass door of the fire- place open. Assure that a continuous gas flow is

at the burner before closing the door.

FIGURE23

W415-0320 / D / 01.06.07