When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condi- tion caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again. Simply open a window to sufficiently ventilate the room.

After extended periods of non-operation such as following a vacation or a warm weather season, the fireplace may emit a slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. Open a window to sufficiently ventilate the room.

PURGE ALL GAS LINES WITH THE GLASS DOOR OF THE FIREPLACE OPEN. ASSURE THAT A CONTINU- OUS GAS FLOW IS AT THE BURNER BEFORE CLOSING THE DOOR.

FOR YOUR SAFETY READ BEFORE LIGHTING:

A. This fireplace is equipped with a pilot which must be lit by hand while following these instructions exactly.

B. Before operating smell all around the fireplace area for gas and next to the floor because some gas is heavier than air and will settle on the floor.

C. Use only your hand to turn the gas control knob. Never use tools. If the knob will not turn by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D. Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and replace any part of the control system and any gas control which has been under wa- ter.

WHAT TO DO IF YOU SMELL GAS

Turn off all gas to the fireplace.

Open windows.

Do not try to light any appliance.

Do not touch any electric switch;

do not use any phone in your building.

Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire de- partment.

FIGURE 55

GAS KNOB

LIGHTING INSTRUCTIONS

WARNING: The gas valve has an interlock device which will not allow the pilot burner to be lit until the thermo- couple has cooled. Allow approximately 60 seconds for the thermocouple to cool.

When lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob is depressed slightly.

1.Stop! Read the above safety information on this label.

2.Turn off all electric power to the fireplace.

3.Turn the gas knob clockwise OPERATING INSTRUCTIONS to off.

4.Wait five (5) minutes to clear out any gas. If you smell gas including near the floor. Stop! Follow "B" in the above safety information on this label. If you don't smell gas go the next step.

5.Turn gas knob counter-clockwise FOR YOUR SAFETY READ BEFORE LIGHTING: to pilot.

6.Depress slightly and hold gas knob while lighting the pilot with the push button ignitor. Keep knob depressed for one minute, then release. If pilot does not con tinue to burn, repeat steps 3 through 5.

7.With pilot lit, depress and turn gas knob counter-clock

wise WHAT TO DO IF YOU SMELL GAS to on.

8.If equipped with remote on-off switch/thermostat, main burner may not come on when you turn valve to on. Remote switch must be in the on position to ignite burner.

9.Turn on all electric power to the fireplace.

FIGURE56

TO TURN OFF GAS

1.Turn off all electric power to the fireplace if service is to be performed.

2.For a complete shut-down procedure: push in gas con-

trol knob slightly and turn clockwiseLIGHTING INSTRUCTIONS to off. Do not force.

3.For a temporary shut-down procedure: set thermostat to lowest setting or remote switch to off. Press and turn

the gas knob clockwise FIGURE56 to pilot.