Napoleon Fireplaces GD70PT-S Mantle Clearances, Example A - Non-Combustiblematerial, Flush Finish

Models: GD70PT-S GD70NT-S

1 28
Download 28 pages 19.04 Kb
Page 15
Image 15
EXAMPLE A - NON-COMBUSTIBLE MATERIAL
W415-0434 / C / 03.24.05
FIGURE 37

EXAMPLE A - NON-COMBUSTIBLE MATERIAL

It is best to frame your fireplace after it is positioned and the vent system is installed. Use 2x4's and frame to local building codes. To install the fireplace face flush with the finished wall, position the framework to accomodate the thickness of the finished wall.

MAINTAIN THESE MINIMUM CLEARANCES TO COM- BUSTIBLES:

Fireplace framing - 0" to stand-offs (top, rear & sides) Fireplace finishing - 3" to sides, 7¼" to top of unit

FIGURE 28

FIGURE 29

FIGURE 30

FLUSH FINISH

To install the fireplace face flush with the finished wall, position the framework to accomodate the thickness of the finished wall.

FIGURE 31

FIGURE 32

15

EXAMPLE B - BEVELLED TRIM

The non-combustible finishing material may be eliminated if the intent is to finish the unit with the optional 6" bevelled trim.

FIGURE 34

FIGURE 35

FIGURE 36

MANTLE CLEARANCES

Combustible mantle clearance can vary according to the mantle depth. Use the graph to help evaluate the clear- ance needed.

**