Napoleon Fireplaces GVFL18P, GVFL30P 4.0FINISHING, 3.3GAS PIPING, 4.1ANDIRON AND GRATE ASSEMBLY

Models: GVFL18N GVFL18 GVFL24N GVFL18P GVFL30N GVFL30 GVFL24P GVFL24 GVFL30P

1 24
Download 24 pages 38.03 Kb
Page 11
Image 11
3.3GAS PIPING

11

3.3GAS PIPING

!WARNING

DO NOT CONNECT EITHER THE WALL SWITCH, THERMOSTAT OR GAS VALVE TO ELECTRICITY

(110 VOLTS).

This appliance and it’s appliance main valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ PSI (3.5kPa)

This appliance must be isolated from the gas supply piping system by closing the individual manual shut off valve during any pressure testing of the gas supply piping system at test pressure equal to or less than ½ psi (3.5 kPa)

3.31Centre the appliance in the appliance opening, making sure the appliance has enough room behind it for the gas line to run behind the log set under the log support.

3.3.2Route the gas line and sizing using piping ½” diameter or greater to allow the full volume of gas to the appliance. The routing of the gas line has to be done to local and / or national codes.

3.3.3When rigid pipe is used an ANSI approved manual shut off and a union must be installed upstream within the appliance cavity.

Regulator

 

Manual

Union

Shut-Off

 

 

Valve

 

 

Fireplace

 

 

Wall

Fireplace

 

Shut-Off

 

Key

 

 

3"

Sediment

 

 

 

 

Trap

 

3.3.4To ensure the appliance operates reliably install a sediment trap upstream of the appliance within the structures of the piping system.

3.3.5When using propane, a regulator must be used between the tank and the outside wall of the house to ensure the line pressure does not exceed 14” w.c.

3.3.6Check gas connections with a gas detection device to test for leaks in the system. Soapy water mixture can also be used to check for leaks.

3.3.7Once all the gas connections are tested for leaks, start the appliance. Follow the lighting instructions to ensure the appliance is working properly before finishing.

4.0FINISHING

4.1ANDIRON AND GRATE ASSEMBLY

4.1.1With the 2 andirons laying face down, secure the grate overtop using 2x ¼-20 bolts (supplied in the

manual baggie).

USE ONLY ACCESSORIES 4.0FINISHING4.1ANDIRON AND GRATE ASSEMBLY DESIGNED FOR AND

LISTED WITH YOUR SPECIFIC LOG SET.

4.1.2Install the grate/andiron assembly to the burner base using 4x ¾” self tapping screws (supplied in the manual baggie).

Manual backgroundManual backgroundManual background1

2

W415-0809 / A / 05.10.10

Page 11
Image 11
Napoleon Fireplaces GVFL18P, GVFL30P, GVFL24N, GVFL24P, GVFL18N 4.0FINISHING, 3.3GAS PIPING, 4.1ANDIRON AND GRATE ASSEMBLY