14
5.0 OPERATING INSTRUCTIONS
If the appliance is equipped with decorative glass doors, they must be fully opened when operating this gas log set.
5.1 LIGHTING INSTRUCTIONS |
|
| 1 |
5.1.1 Locate the pilot burner at the rear of the log set on the right |
| ||
|
| ||
side. |
|
|
|
5.1.2 Turn the gas control knob to the pilot setting |
|
|
|
(on the left side of the appliance closest to the |
|
|
|
back). |
|
|
|
5.1.3 With the control knob depressed, push the |
|
|
|
piezo igniter continuously until the pilot lights. |
|
|
|
Hold the control knob in for 1 minute and re- |
|
|
|
lease. If the pilot goes out, repeat steps 2 and |
|
|
|
3. |
|
|
|
5.1.4 Once the pilot stays burning, make certain that | 2 |
|
|
the on / off switch is in the off position. Turn |
|
|
|
the control knob | 3 | 4 |
|
position. |
| 5 | |
5.1.5 Turn the on / off switch to the on position to ignite the |
| ||
|
|
burner. This appliance must be isolated from the gas supply piping system by closing the individual manual shut off valve
during any pressure testing of the gas supply piping system at test pressure equal to or less than ½ psi (3.5 kPa).
If appliance shuts off, do not relight until you provide fresh air. If appliance keeps shutting off, have it serviced. Keep burner and control compartment clean.
When lit for the first time, the appliance will emit a slight odour for a few hours. This is a normal temporary con- dition caused by the curing of the logs and the
5.2MATCH LIGHTING INSTRUCTIONS
5.2.1Remove any items necessary for easy access to the ODS (for example: logs, screens, etc.).
5.2.2Follow appropriate lighting instructions found previously. Instead of pushing and releasing the piezo button, light a match and hold the flame to the end of the pilot and ignite the pilot.
5.2.3After control knob has been released and pilot stays lit, reinstall any items that were removed for pilot access.
5.2.4Call a qualified service technician for repair or replacement of the piezo ignitor.
After extended periods of
Purge the gas line with the glass door open. Assure that a continuous gas flow is at the burner before closing the door.