Chapter 3 Signal Connections
©
National Instruments Corporation 3-3 DAQArb 5411 Use r Manual
SYNC ConnectorThe SYNC connector is a transistor-trans isto r- lo gi c (T TL) ve rsio n o f
the sine waveform being generated at the output. You can think of the
SYNC output as a very high frequency resolution,
software-programmable clock source for many applications. You can
also vary the duty cycle of SYNC output on the fly by software control,
as shown in Figure3-3. tp is the time period of the sine wave being
generated and tw is the pulse width of the SYNC output. The duty cycle
is (tw/tp)x 100 %.
Figure 3-3. SYNC Output and Duty Cycle
You can route the SYNC output to the RTSI lines over the RTSI bus.
The SYNC output is derived from a comparator connecte d to the analog
waveform and is intended to be used when the waveform is a sine
function. The SYNC output will provide a meaningful waveform only
when you are generating a sine wave on the ARB output. For more
information on SYNC output, see Chapter 4, Arb Operation.
PLL Ref ConnectorThe PLL Ref connector is a phase-locked loop (PLL) input connector
that can accept a reference clock from an external sour ce and ph ase lock
the DAQArb internal clock to this external clock. The reference clock
should not deviate more than ±100 ppm of its nominal frequency. The
minimum amplitude levels of 1 Vpp are required on this clock. You can
lock reference clock frequencies of 1 MHz and 5–20 MHz in 1 MHz
steps.
Note: You can also lock the DAQArb 5411 to other National Instruments cards
over the RTSI bus using the 20 MHz RTSI clock signal.
ARB Output
t
p
SYNC Output
(50% Duty Cycle)
SYNC Output
(33% Duty Cycle)
t
w