Chapter 4 Connecting Signals
NI PCI-6110/6111 User Manual 4-26 ni.com
SISOURCE SignalAny PFI pin can receive as an input the SISOURCE signal, which is not 
available as an output on the I/O connector. The SI2 uses SISOURCE as 
aclock to time the generation of the STARTSCAN signal. You must 
configure the PFI pin you select as the source for SISOURCE in the 
level-detection mode. You can configure the polarity selection for the 
PFIpin for either active high or active low.
The maximum allowed frequency is 20 MHz, with a minimum pulse width 
of 23 ns high or low. There is no minimum frequency limitati on.
Either the 20MHz or 100 kHz internal timebase generates SISOURCE 
unless you select some external source. Figure4-19 shows the timing 
requirements for SISOURCE.
Figure 4-19.  SISOURCE Signal Timing
SCANCLK SignalSCANCLK is an output-only signal that generates a pulse with the leading 
edge occurring approximately 50 to 100ns after an A/D conversion begins. 
The polarity of this output is software-selectable, but it is typically 
configured so that a low-to-high leading edge can clock external AI 
multiplexers indicating when the input signal has been sampled and can be 
removed. This signal has a 450 ns pulse width and is software enabled. 
Note SCANCLK polarity is low-to-high and cannot be changed programmatically using 
NI-DAQ.
t
w 
= 23 ns minimum
t
p 
= 50 ns minimum
t
p
t
w
t
w