©NationalInstruments Corporation A-1 PXI-1006User Manual
ASpecifications
This appendix contains specificationsfor the PXI-1006 chassi s.
Electrical
AC Input
Inputvoltage range.................................90–264 VAC
Inputfrequency range ............................ 47 to 63 Hz
Over-currentprotection ..........................10 A circuit breaker
Maximum steady state
operatingcurrent .................................... 10 A
Line regulation....................................... ± 0.1% overoperating line range
Efficiency...............................................70-80% typical
Powerdisconnect ................................... The (standby) power switch
causest he powermodule to
supply DC powerto
theCompactPCI/PXI backplane.
The rear-panelD-sub connector
facilitatesr emote inhibiting
operation. The (standby) switch
mustbe in the On position prior to
use of remote inhibit. The power
cord providesmain power
disconnect.