AppendixA Specifications
PXI-1006User Manual A-4 ni.com
Functional shock (operating) .................. MIL-T-28800E CLASS 3,
Half-Sine Shock Pulse, 11 ms
duration, 30 g peak
Operatinglocation ..................................Indoor use only
Random vibration
Operational1.....................................5to 500 Hz, 0.31 gRMS
Non-operational1.............................10to 500 Hz, 2.46 gRMS
EMCemissions .......................................FCC Class A compliant and
EN 55011 Group 1 Class A
Compliant
EMCimmunity .......................................Refer to DOC supplied with
chassis for compliance to
relevantdirectives.
Altitude...................................................2 km (1.24 mi) max
Backplane
Size.........................................................3U-sized; one system slot
(with three system expansion
slots) and17peripheralslots.
Compliantwith IEEE 1101.10
mechanicalpackaging.
PXIS pecificationRevision 2.0
compliant.
Acceptsboth PXI and
CompactPCI( PICMG 2.0 R3.0)
3U modules.
Backplane bare-board material...............UL 94 V-0 recognized
Backplane connectors.............................Conform to IEC 917 and
IEC 1076-4-101, and are
UL 94 V-0rated
1Randomvibration profiles were developed in accordance with MIL-T-28800E CLASS 3 and MIL-STD-810E Method 514
Testlevels exceed those recommended in MIL-STD-810E for Category 1 (Basic Transportation), Figures 514.4-1 through
514.4-3.