Alarm Control

The alarm generates a beeping sound when one or more physical disks fail. The sound continues until Silence Alarm is selected. After a rebuild finishes, a beep signals that the rebuild is done. Choose Silence Alarm at this time to silence the alarm. The alarm settings are:

Setting

Description

Enable / Disable

When Alarm Control option is selected and if Disable Alarm

Alarm

appears, the alarm is enabled and can be disabled. If Enable Alarm

 

appears, the alarm is disabled and can be enabled. When Enable

 

Alarm is set, a beeping sound occurs even when all logical drives

 

are online and there are no failed disks after a hot spare rebuild

 

completes. Use the Silence Alarm function to stop the alarm.

Silence Alarm

Stops the alarm if it is currently beeping. If the alarm is not beeping,

 

it has no effect.

Fast Initialization

Specify whether to perform fast initialization. Always set to "Enable" (default).

Battery Status

The battery information on a controller is displayed.

S.M.A.R.T. Setting

S.M.A.R.T. Set up a function. Please do not change.

33