Step 3 – Facilities (Conf_Room_Sch only)

Conference Room Scheduler Installation Guide

Application Configuration

Step 3 – Facilities (Conf_Room_Sch only)

According to instructions in the APM Operations Manual, designate the following NEAX2400 facilities for the Conf_Room_Sch component using the Facilities command on the APM Configuration Entry screen:

MRFI

Mode Release Facility (I)

MRFR

Mode Release Facility (R)

MSF

OAI Mode Set Facility

NTF

Number Transfer Facility

TCFD

Terminal Control Facility (D)

Note: The same MSF identification number (i.e., from 128 to 192) that is selected in the

APM during Step 3 must be assigned to Conference Room Scheduler at the NEAX

MAT. For more information, see Chapter 4 .

Step 4 – Secondary OAI Configuration Parameters (Conf_Room_Sch only)

Using the OAI-Confcommand on the APM Configuration Entry screen, make the entry shown for each of the following parameters required by Conf_Room_Sch. Use the instructions provided for this option in the APM Operations Manual:

Parameter

Entry

Definition

 

 

 

Database Name #1

/oai/db/cur/crminfofil

Indicates the path name of the database

 

 

containing the conference room

 

 

information. This name must be the

 

 

first listed database. The database

 

 

filename (i.e., crminfofil), listed here

 

 

with its path, should be used as the

 

 

name of the corresponding Application

 

 

Definition File (Refer to Chapter 3.)

 

 

 

Database Name #2

/oai/db/cur/crmidfile

Indicates the path name of the database

 

 

containing the employee identification

 

 

data. This name must be the second

 

 

listed database. The database filename

 

 

(i.e., crmidfile), listed here with its

 

 

path, should be used as the name of the

 

 

corresponding Application Definition

 

 

File (Refer to Chapter 3.)

 

 

 

Timeout Value #1

90

Designates the number of seconds

 

 

Conf_Room_Sch will wait for user

 

 

input before it will release the Dterm.

Tenant Number

0

Specifies the number of the tenant that

 

 

Conf_Room_Sch serves.

 

 

 