CHAPTER 1 CUSTOMIZING OFFICE DATA

How to Customize Office Data

HOW TO CUSTOMIZE OFFICE DATA

This section explains how to customize the office data.

The Customer Specifications Sheet” section provides the data tables for the following items:

Numbering Plan

The Numbering Plan Data Table (Table 1-1) specifies the service feature access codes, trunk access code, station numbers and other special access codes.

Service feature access codes and trunk access codes are given to each service feature and each trunk route respectively with a maximum of four digits code. The station numbers are specified by a maximum of eight digits.

For the numbering plan of the system, consider the following conditions:

(1)The same first digit code cannot be assigned to the other features within the programmed Numbering Plan Group. (This condition is not applicable to the system providing the Single Digit Timing Start Access.)

(2)The feature access codes should be three or four digits, because plural access codes for each feature are required.

(3)There are eight types of station numbering (1 digit - 8 digits). Any combination of these types is available in one system.

(4)The same station number cannot be assigned, even if the tenant service is applied.

Station Data

In Station Data Table (Table 1-2), the following data is required:

Station Number

Up to 8 digits station numbers specified in the Numbering Plan Table are assigned. For the Dterm station, specify the My Line number.