CHAPTER 1 CUSTOMIZING OFFICE DATA
How to Customize Office Data
•NUMBER OF LINE
Specify the number of trunks to be provided with each route Incoming (IC), Outgoing (OG), Bothway (BW)
•DP/PB
Specify the type of address signal from/to distant office, as follows:
TYPE OF TEL |
| DESCRIPTION |
DP | Dial Pulse | |
PB | DTMF Signal |
•KIND OF SIGNAL
Specify the kind of signaling system such as Ring Down, Loop, E & M, etc. at the line.
Station Hunting Group Data
In Station Hunting Group Data Table (Table
•KIND OF STATION HUNTING
Specify the kind of the Station Hunting System (Pilot/Circular/Switch Back). For the Pilot System, specify the Pilot Station number.
•SECRETARY STATION
Specify the Secretary Station number, if provided.
•STATION NUMBER
Specify the station numbers to be assigned to the Station Hunting Group with the following conditions.
(1)Up to 60 stations can be assigned per Station Hunting Group.
(2)There is no limitation to the number of Station Hunting Group.
(3)The same one station cannot be assigned to multiple Hunting Groups.
Page 8 | NEAX2000 IVS2 Office Data Programming Manual |