Label roll snapped

Check if too tight coming thru

 

cartridge

 

 

 

 

Defective label roll/replace

 

Defective dc motor

Replace motor

Scale say unload or help

possible load cell

Contact dealer

 

damage

 

 

 

 

Strange characters on

Corrupted memory

Go to config/total reset/reset scales

 

display

memory (all data will be lost)

 

 

 

Scale drifts

Vibration or air blowing

Relocate scale to hard/quiet area.

 

on platter

 

 

 

 

Quick access keys show

 

Press ESC. Press ABC button to turn

 

only a letter or other

In ABC mode

 

off

 

character when pressed

 

 

 

 

 

 

 

 

 

If you are experiencing mechanical problems you must contact your dealer first! It is up to your dealer to decide a course of action to take to resolve any matter concerning your scale. No returns will be accepted without a return authorization number. You may contact us for any technical questions you might have. Please read carefully the warranty sheet supplied with the scale.

Page 24
Image 24
Network Computing Devices LSQ-40L quick start manual