NTI VEEMUX VIDEO MATRIX SWITCH

ETHERNET CONTROL

Telnet Interface

The Telnet Interface enables the user to control the switch using telnet client through an Ethernet connection. The telnet server listens on port 2000. To access the telnet interface, using the current IP address type the following in a command shell:

telnet 192.168.1.30 2000

The VEEMUX will prompt the user for a password. The user must enter the password followed by <Enter>.

The factory default password is "admin".

With a proper password sent the VEEMUX will respond with:

Password Successful

Connection Established

The following commands are now available:

 

Command

 

Reply

 

Description

 

 

 

 

 

 

 

H(elp) or

 

Displays the list of

 

Help

 

h(elp)

 

commands

 

 

 

 

 

 

 

 

User is prompted to

 

 

 

CP

 

introduce the password

 

Change password

 

 

 

twice

 

 

 

CS nn,mm

 

*<CR>

 

Connect One Output (User Port) To Input (Video source)

 

 

 

 

 

 

 

CA nn

 

*<CR>

 

Connect All Outputs To Input

 

 

 

 

 

 

 

RO nn

 

*<CR>mm<CR>

 

Read Connection For Output.

 

 

 

Returns the number of the input (mm) connected to output nn

 

 

 

 

 

 

CC nn

 

*<CR>nn<CR>

 

Save Matrix Connections Into Memory Bank nn

 

 

 

nn should be between 00 and 99

 

 

 

 

 

 

RC nn

 

*<CR>nn<CR>

 

Restore Matrix Connections From Memory Bank nn

 

 

 

nn should be between 00 and 99

 

 

 

 

 

 

CB nn

 

*<CR>

 

Change baud rate of serial line, nn=12(00),24(00),48(00),96(00)

 

 

 

Factory default is 9,600.

 

 

 

 

 

 

RS

 

*<CR>

Reset Unit

 

 

 

 

 

 

RV 00

 

*<CR>string\0<CR>

Read NTI Version String

 

 

 

 

 

 

 

RU

 

*<CR>nn,mm<CR>

 

Read Unit Size

 

 

 

Returns the number of inputs(nn) and the number of outputs (mm)

 

 

 

 

 

 

Ss nn,dwt

*<CR>

 

Set value of Scan Mode dwell time (see pg. 8) for specific Output (nn)

 

 

dwt = 000-255 (seconds) 000= disable Scan Mode

 

 

 

 

 

 

Gs nn

 

*<CR>

 

Read set Scan Mode dwell time value (dwt) for specific Output (nn) in

 

 

dwt<CR>

 

seconds (see also "Scan Mode" on page 8)

 

 

 

 

 

Sa nn,mm

 

*<CR>

 

Set scan list of individual output nn to all inputs mm

 

 

 

 

 

 

 

Sc nn

 

*<CR>

 

Clear scan list of individual output nn

 

 

 

 

 

 

S+ nn,mm

*<CR>

 

Add input mm to Scan List of output nn

 

 

 

 

 

 

 

S- nn,mm

 

*<CR>

 

Remove input mm from Scan List of output nn

 

 

 

 

 

 

 

Sx nn

 

*<CR>oooxoxxxooooxxx<

 

Display the Scan List of output nn (o=skip x=don't skip)

 

 

CR>

 

 

 

 

 

 

 

<Ctrl>-<X>

 

Good Bye.

 

Quit telnet session

 

(see note 4 below)

 

Connection to host lost.

 

 

 

 

 

13