NTI VEEMUX VIDEO MATRIX SWITCH

Update Firmware

For updating the Ethernet Control, use this section and insert the file v1_x.bin

For updating the Front Panel LCD, use this section and insert the file rmtlcd_va_1_x. hex

Figure 15- Web interface Update Firmware page

The Update Firmware page (located in the main menu under "ADMINISTRATION") shows the current version of the firmware for the Web interface (Fig-15-upper) and for the Front panel (Fig-15-lower) and enables the Administrator to update the firmware of the VEEMUX.

WARNING: Failure to carefully follow these directions can permanently damage the VEEMUX. Please read these directions in full before continuing. Do not, under any circumstances, reset or power-down the VEEMUX while the firmware is being updated. Do not attempt to update the firmware if a power-failure is likely.

Note: The Firmware can only be updated from the non-secure (http) website. If you attempt to access this page from the secure (https) website, you will be automatically redirected to the non-secure site.

To update the firmware:

1.Contact NTI for the latest firmware file (see Fig. 15) and copy it to your computer.

2.On the Update Firmware page, in the section to be updated, browse to the firmware file.

3.Press Update Firmware (for the Ethernet Control) or Update Front Panel Firmware (for the LCD).

Note: If an update is attempted using the wrong firmware for the section an error message will be received. No update will occur.

4. Wait for the following message to appear (may take several minutes):

Upload Succeeded

Flash of new image completed:

The system will automatically restart.

5.The VEEMUX will restart itself in 10 seconds, logging out all connections. After approximately 40 seconds, the VEEMUX will be ready to resume operation.

If a message appears stating that the Upload has failed, or that a non-fatal error has occurred:

1.Ensure that the file being uploaded is the NTI firmware file.

2.Repeat the process from step 2 above.

Note: The following message does not indicate that damage to the product has occurred.

If a message appears stating that there has been a fatal error:

1.DO NOT RESET OR POWER-DOWN THE VEEMUX.

2.Repeat the update process from the first step 2 above.

3.If you get another Fatal Error message, call NTI tech-support at 1-800-742-8324 or 330- 562-7070.

FYI: The VEEMUX should continue to run normally unless it is reset. However, damage may have occurred to the web server firmware that will prevent the product from starting up correctly.