Network Technologies ST-C5V2ARS-1000S Index, The picture on the monitor, than color, typed, Cause

Models: ST-C5KVM2ARS-1000S ST-C5V2ARS-1000S

1 21
Download 21 pages 44.65 Kb
Page 20
Image 20
The picture on the monitor

NTI XTENDEX Extenders

Problem

Cause

 

Solution

The picture on the monitor

The video cable was not attached to

 

With the cables all properly connected, reboot the CPU.

is black and white, rather

the CPU when it was booted.

 

 

 

than color

 

 

 

 

 

A constant vertical wobble

CAT5 cable is too close to a strong

 

Reroute CAT5 cable if possible.

appears down the screen

power source.

 

 

 

Monitor sometimes loses

Electrical power system is very

 

Make sure the interconnection cable is not near any

sync, causing it to go

 

noisy, particularly the ground.

 

 

power lines.

blank for a second or two

The CAT5 cable is not properly

 

Check cable connections. Make sure they are snapped-

 

 

connected.

 

 

in properly and completely.

Wrong or missing

The keyboard may be in the wrong

 

Disconnect keyboard at Remote Unit end and reconnect.

characters from those

mode.

 

Reboot the system.

typed

 

 

 

 

 

CPU doesn't detect the

Keyboard cable or mouse cable

 

Check cable connections

keyboard and the mouse

 

are loose or reversed

 

Cat 5 cable can be no more than 1000 feet in length

 

Cat 5 cable is too long

 

 

 

 

 

IBM Scroll Point mouse is

Only one IBM Scroll Point mouse is

 

In order for an IBM Scroll Point mouse to be recognized,

not recognized by CPU

connected at either the Local or

 

 

an IBM Scroll Point mouse must be connected at both

 

Remote unit

 

 

the Local and Remote extender units. Otherwise it will

 

 

 

 

 

be recognized and work only as a Microsoft Intellimouse.

Image is not displayed

Signal is being skewed by the CAT5

 

Check the user's manual for the monitor, projector, or

properly, lacks definition

cable and not being received correctly

 

 

display equipment for an "automatic adjustment" or

 

by the monitor .

 

 

"auto-configure". This is most common to LCD type

 

 

 

 

 

monitors.

Models with RS232 Support

 

 

 

 

 

No RS232 communication

One or more RS232 cables is

 

Check all RS232 cable connections

 

 

loose or disconnected

 

 

 

Models with audio Support

 

 

 

 

 

No audio

Audio cable is not properly

 

Check all cable connections

 

 

plugged in

 

 

 

 

Speakers are not plugged in

 

Verify speakers are connected and powered

 

CAT5 cable is not properly

 

Check CAT5 cable connections

 

 

connected

 

 

 

Microphone not working at

Active microphone not set

 

Set microphone to be active where it is connected, at

either Local or Remote

 

properly

 

 

either the Local or Remote unit (not both). See pages 12

 

 

 

 

 

(models without keyboard support) or 13 (models with

 

 

 

 

 

keyboard support) for instruction on setting the active

 

 

 

 

 

microphone.

INDEX

Audio connectors, 7 Cat5 cable wiring, 16 Command mode, 13 DDC, 12, 13 extension cables, 2 Feature support, 1 install the Local Unit, 6 install the Remote Unit, 9 installation preparation, 5

IR controls, 1 limitations, 5 materials included, 2 microphone use, 5, 10 Mode button, 12 RS232 adapter, 8

Technical Specifications, 15 test patterns for skew, 12 Video quality adjustment, 12