2. Set Hodel ZC-80 unit in place and attach safety shield to unit as shown in Figure i-A and i-B. You must place a noncom- bustible material 3/4" thick millboard or equivalent K Factor =.084/BTU/F 2 H0F inches minimum.

2. Set Hodel ZC-80 unit in place and attach safety shield to unit as shown in Figure i-A and i-B. You must place a noncom- bustible material 3/4" thick millboard or equivalent K Factor =.084/BTU/F 2 H0F inches minimum.

3. Frame the ZC Cabinet usng 2"x 4" studs or local building code

framing. Some minor framing restrictions are required:

A.Adjacent side walls must be at least 6" from the outer edge of the Cabinet trim panel.

B.The overall opening dimensions must be at least 47 1/2" Hide and 41 1/2" high.

C. Framing must protrude 2 1/2" to allow for finished wall to come flush with the back of the ZC Cabinet trim panel (See Fig- ures i-A and i-B).