New Buck Corporation 80ZC manual Exterior Roof Or Chase

Models: 80ZC

1 18
Download 18 pages 13.71 Kb
Page 11
Image 11
FIGURE 7 EXTERIOR ROOF OR CHASE

Chimney Cap

//?~--Chimney Pipe

CAUTION! Refer to chimney manufacturers instructions for assembly and disassembly of

chimney parts. Be sure to follow chimney instructions for proper clearances to combusti- bles and proper air spacing required.

"Y~.....4-'::;"':~-- 2" x." Siudding

Doubl. H••der

-+1----A Double Header must be used on a

load bearing wall. This must be done 12" above cabinet.

Singi. H••der

A Single Header must be used as part of front Iraming, vertical 2" ....·s

must be turned flat.

NOTE: Finished wall must be 2" in front of face of Z.C. Cabinet (without hood panell.

WARNING! Install the hearth protector only as specified. The hearth extension must extend a minimum of 16" in front of the fireplace opening and must be 47 1/2" wide mini- mum.

FIGURE 7 EXTERIOR ROOF OR CHASE

9

Page 11
Image 11
New Buck Corporation 80ZC manual Exterior Roof Or Chase