FIGURE 8 CORNER LOCATION FRAMING

CAUTION! Refer to chimney manufacturers instructions for assembly and disassembly of

chimney parts. Be sure to follow chimney instructions for proper clearances to combusti- bles and proper air spacing required.

ffi --- Chimney Cap

0--\.--1-Storm Collar

---:f --Roof Flashing

-+Chimney Pipe

,.....e;~~"'-7"'5..-s-'lt-ttt1-- Use Fire Code Sheet Rock

-"'C-~7"''-?.-s-'S1'f--i-H-tt+f--Met al Fire Slop

NOTE:

A Double Header must be used on a

load bearong ....all as illustrated in

F.gure 3.

2" • 4" Studding

"-':H+f--t-+++H+--A Single Header must be Installed above cabinet.

Vert.cal 2" • 4'''smust be turned flat.

NOTE:

Finished wall must be 2" in front of face of Z.C. Cabinet (without hood trim attached) .

WARNING! Install the hearth protector only as specified. The hearth extension must extend a minimum of 16" in front of the fireplace opening and must be 47 1/2" wide mini-

FIGURE 8 CORNER LOCATION FRAMING

10