Framing must be accomplished after the Model ZC-80 is set in

place. The chimney can be installed after framing, but installa - tion is considerably more difficult and, in some cases, impossi-

ble. Therefore, it is recommended that the chimney be installed prior to framing when a choice exists.

'~ ~t:

LJ ± lZ

rr~'Bl.lllzm<f1~mm_"

Atlj<lcelll noom 01

~

~\~ :Jl.

Exlclior Cha:;e

 

 

 

 

Interior

 

 

Locntion

FIGURE 6

Above (Figure 6) are framing location examples with depth dimen-

sions for some typical configurations. These are finished meas- urements so install accordingly.

1. Before framing, combustible floor coverings (carpet, tiles, etc.) must be removed to outer dimension of unit framing, includ- ing the 16" x 42 1/2" area for the hearth extension.

FIGURE 1·A:Safety shield for millboard hearth extension.

Attach safety shield using sheet metal screws

WARNING! Install the hearth protector only as specified. The hearth extension must extend a minimum of 16" in front of the fireplace opening and must be 42 1/2" wide mini- mum.

FIGURE 1-B: Safety shields for

brick or rock hearth (Note: Cut vertical shield to Fit Installation

height as needed. Use 26 'Ga. Mini- mum metal being sure to cover any combustibles on the base.)

o

"'==~~--7'Attach safety shield using sheet metal

scews

7