FRAMING CONSTRUCTION

FRAMING CONSTRUCTION

Except as noted, the Hodel ZC-80 can be installed almost anywhere

you desire. There are, however, a few clearance and framing

restrictions that must be followed. See figures 1 and 2 to make

sure that these clearance restrictions are met. It is much wiser to place your Hodel ZC-80 correctly at the start of the installa- tion than to be forced to relocate it after much of the work is done.

You must ensure that the floor is of adequate strength to accept

the load of this unit. If inadequate, the floor will require additional support, such as bracing. A wooden base constructed of plywood or 2" x boards is required in order to get a raised hearth look.

Good planning is essential for a satisfactory installation, therefore, at this point you should have decided where the Hodel ZC-80 ivill be located and the route the chimney will follow to

the roof-straight up, or chase. If you cannot decide the best route, contact your Buck Stove Dealer for assistance with the planning.

CHIMNEY INSTALLATIONS

Position Hodel ZC-80 for chimney installation as follows:

A.Thoroughly clean the area where the unit will be placed.

B.Layout the location on the floor and construct base (See Figure 5).

C.If chimney is to be installed through a ceiling, drop a plumbline, locate, and mark point on ceiling directly over center of Model ZC-80 chimney adapter.

D. Install the chimney in accordance with chimney manufacturer's recommendations.

CAUTION: Follow the instructions for the type chimney you're building, i . e . , straight-up or chase. For minimum height and maximum height follow chimney manufacturers instructions.

Finished Wall

 

 

 

Finished Hearth

 

 

 

A

Floorline

 

 

""'1

 

16" __~

 

Wooden Base

:::~

 

 

FIGURE

1

 

 

 

 

 

5'

 

19'/."

 

 

 

 

 

 

 

 

WARNING! Install the hearth protector only as specified. The hearth extension must extend a minimum of 16" in front of the fireplace opening and must be 42 1/2" wide mini- mum. (Total area to be covered is 19 3/4" by 42 1/2" . )

Base for Hodel ZC-80 must be level with or slightly higher than finished hearth height-dimension (A) Figure 5. Front of cabinet must be recessed 2 1/2" from finished wall.

6