CLEARANCES FOR MODEL 94NC

CLEARANCES FOR MODEL 94NC

MINIMUM CLEARANCES TO COMBUSTIBLES RESIDENTIAL SINGLE WALL CONNECTOR

 

 

BACK WALL

 

 

C

B

BH C FF

CD

D

SIDE WALL

 

 

 

 

 

E

 

G

 

 

A

 

 

 

Figure 13

 

A

B

C

D

E

F

G

H

MODEL 94NC

5"

8"

10.5"

8"

8"

6"

20"

10”

 

22”

23”

26”

23”

8”

6”

16”

12”

NOTE: All clearances are to combustibles using single wall pipe, minimum floor protector. Minimum floor protection under unit must have an R-value of 0.30. (see page 12, 13)

NOTE: The clearances above may be reduced, follow NFPA-211 codes.

For wall exit, Floor protector must be under horizontal pipe the length between stove and exit. Must be 2” on each side of pipe. Maintain 18" between pipe and ceiling. (See Figure 13, measurements F & H ).