New Buck Corporation 94NC Section Troubleshooting, Problem, Possible Cause, Solution

Models: 94NC

1 29
Download 29 pages 51.28 Kb
Page 25
Image 25
SECTION VIII

SECTION VIII

TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

SOLUTION

 

 

 

Sluggish Heater

Obstruction in chimney

Check for and remove

 

 

obstruction

Improperly sealed trim kit or direct connect kit

(a)Check trim kit gasketing seal to fireplace and gasket as necessary to seal unit. Gasket under front bottom of stove if needed.

(b)Check seal if using direct connect and correct.

Manual damper in chimney is closed

Open manual damper and wire shut with stainless steel wire or remove damper

Wet or unseasoned wood

Burn dry, natural seasoned

being burned

hard wood

Poor chimney draft

Improper chimney height or

 

wrong size flue is being used.

 

Cooler temperatures caused

 

by external chimney

Improper wood loading

Load wood length way from

 

front to rear

Page 23

Page 25
Image 25
New Buck Corporation 94NC installation instructions Section Troubleshooting, Problem, Possible Cause, Solution