TROUBLESHOOTING
(Continued)
PROBLEM | POSSIBLE CAUSE | SOLUTION |
|
|
|
High fuel consumption | Improper regulation of draft | (a) Close inlet air control as |
| or inlet air | much as possible to |
|
| maintain desired heat |
|
| output |
|
| (b) Check gaskets, reinstall |
|
| fiberglass gasketing |
|
| round doors and glass as |
|
| necessary |
| Improper door fitting | Check door gasket, check |
|
| adjustment of door latch |
|
|
|
Backpuffing | Gusts of Wind | (a) Smoke shelf in chimney |
|
| is filled with creosote & |
|
| ash |
|
| (b) Chimney may need wind |
|
| diverter. Raise chimney |
|
| for better draft |
Smoke rollout when heater | Wind gusts blowing down the |
door is opened | chimney |
(a)Smoke shelf in chimney is filled with creosote & ash
(b)Chimney may need wind diverter. Raise chimney for better draft
Opening heater door too fast | Crack door for 15 seconds |
| before fully opening door |
Page 24