New Buck Corporation CR8T manual Air in gas lines when

Models: CR8T

1 39
Download 39 pages 49.98 Kb
Page 31
Image 31
27
3. Safety interlock system has been triggered ( if equipped)
4. Manual shutoff valve not fully open
5. Thermocouple connection loose at control valve
6. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem can be caused by one or both of the following:
A) low gas pressure B) dirty or partially clogged ODS/PILOT
7. Control valve damaged
1. Control knob is not fully pressed in
2. Control knob not pressed in long enough

4. Air in gas lines when

4. Continue to hold down control

installed

knob. Repeat igniting

 

 

operation until air is removed.

5.

Depleted gas supply

5. Contact local propane gas company

6.

ODS/PILOT is clogged 6. Clean ODS/PILOT or replace

 

 

ODS/PILOT assembly

7.

Gas regulator setting is

7. Replace gas regulator

 

not correct

 

OBSERVED

POSSIBLE

 

PROBLEM

PROBLEM

SOLUTION

ODS/PILOT lights but flame goes out when control knob is released

1.Press in control knob completely

2.After ODS/PILOT lights keep control knob pressed in 30 seconds

3.Wait 1 minute for safety interlock system to reset

4.Fully open manual shutoff valve

5.Hand tighten until snug, then tighten 1/4 turn

6.A) Contact local propane gas company

B) Clean ODS/PILOT (See Cleaning and Maintenance), or replace ODS/PILOT assembly

7. Replace control valve