SECTION VI VENTED
(1)This appliance must be installed only in a
and constructed of |
|
(2) A minimum of 25.7 sq. in. (Min. 6” chimney) or see page 24, permanent flue opening | must be |
provided by either the fireplace chimney or chimney damper to vent the flue gases. |
|
(3)Obtain a Damper Flap Lock from your dealer or manufacture. Adjust the Lock on the side of the damper flap in position to maintain a permanent opening of 25.7 sq. in. and lock in place.
(4)Solid fuels shall not be burned in a fireplace where a decorative appliance is installed.
DAMPER
FLAP
DAMPER FLAP
LOCK
FIGURE 8
(5)Any chimney damper must be fixed in a manner which will maintain the minimum permanent vent opening at all times.
NOTE: See chart on page 24.
(6) Periodic cleaning of the venting system of a solid fuel burning fireplace should be done by a quali- fied agency. Clean once a year.
Periodic examination and cleaning of the venting system of a solid fuel burning fireplace should be done once a year.
MINIMUM FIREPLACE DIMENSIONS FOR CR8T LOG SET MANUFACTURED BY NEW BUCK CORPORATION FOR SOLID FUEL BURNING FIREPLACE OR MASONRY FIRE- PLACE AND PREFAB OR MANUFACTURED FIREPLACES.
MODEL | HEIGHT OF | WIDTH OF | WIDTH AT | DEPTH OF |
| OPENING | OPENING | REAR | FIREPLACE |
CR8T |
| AT FRONT |
|
|
17” | 24” | 18” | 10” |
23