SECTION VI VENTED

SECTION VI VENTED

(1)This appliance must be installed only in a solid-fuel burning fireplace with a working flue

and constructed of non-combustible materials.

 

(2) A minimum of 25.7 sq. in. (Min. 6” chimney) or see page 24, permanent flue opening

must be

provided by either the fireplace chimney or chimney damper to vent the flue gases.

 

(3)Obtain a Damper Flap Lock from your dealer or manufacture. Adjust the Lock on the side of the damper flap in position to maintain a permanent opening of 25.7 sq. in. and lock in place.

(4)Solid fuels shall not be burned in a fireplace where a decorative appliance is installed.

DAMPER

FLAP

DAMPER FLAP

LOCK

FIGURE 8

(5)Any chimney damper must be fixed in a manner which will maintain the minimum permanent vent opening at all times.

NOTE: See chart on page 24.

(6) Periodic cleaning of the venting system of a solid fuel burning fireplace should be done by a quali- fied agency. Clean once a year.

Periodic examination and cleaning of the venting system of a solid fuel burning fireplace should be done once a year.

MINIMUM FIREPLACE DIMENSIONS FOR CR8T LOG SET MANUFACTURED BY NEW BUCK CORPORATION FOR SOLID FUEL BURNING FIREPLACE OR MASONRY FIRE- PLACE AND PREFAB OR MANUFACTURED FIREPLACES.

MODEL

HEIGHT OF

WIDTH OF

WIDTH AT

DEPTH OF

 

OPENING

OPENING

REAR

FIREPLACE

CR8T

 

AT FRONT

 

 

17”

24”

18”

10”