IMPORTANT: Operating heater where impurities in the air exist may create odors.

Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles , etc. create fumes. These fumes may mix with combustion air and create odors.

 

OBSERVED

POSSIBLE

 

 

PROBLEM

CAUSE

SOLUTION

 

Heater produces a clicking/ticking

1. Metal expands while heating 1. This is common with

 

noise just after burner is lit or shut

or contracts while cooling

most heaters. If noise is

 

off

 

excessive, contact a

 

 

 

qualified service person.

 

 

 

 

 

Heater produces unwanted odors

1. Heater burning vapors from

1. Ventilate room. Stop

 

 

paint, hair spray, glues, etc.

using odor causing

 

 

(See “Important” above)

products while heater is

 

 

 

running.

 

 

2. Low fuel supply

2. Refill supply tank.

 

 

3. Gas leak (See WARNING

3. Locate and control all

 

 

above)

leaks. See “ Checking

 

 

 

Gas Connections”.

 

 

 

 

 

Heater shuts off in use

1. Not enough fresh air is

1. Open window/door for

 

(ODS operates)

available

ventilation

 

 

2. Low line pressure

2. Contact local propane

 

 

 

company

 

 

3. ODS/PILOT is partially

3. Clean ODS/PILOT

 

 

clogged

 

 

 

 

 

 

Gas odor even when control knob

1. Gas leak (see WARNING

1. Locate and correct all

 

is in OFF position

above)

leaks (see Checking Gas

 

 

 

Connections)

 

 

2. Control valve defective

2. Replace control valve

29