Pressing A button at any moment within the list of recalled results brings the unit to Ready to Measure mode.

Choosing cLr at the end of recalled data will erase the device memory.

Additional display information

Additional indication is displayed in Ready to Measure mode:

Y or M

Indicates that distance is displayed in yards or

meters; elevation may or may not be measured

 

°Indicates that only azimuth or elevation is measured

KMH or

Indicated speed is displayed in either kilometres

MPH

per hour or miles per hour

Reliability of ranging depends on the number of impulses that reflect from the target and reach the unit. The unit informs the user:

TARGET REFLECTION LOW ranging results have low statistical reliability,

TARGET REFLECTION MED – ranging results have

medium statistical reliability,

TARGET REFLECTION HIGH – ranging results have

high statistical reliability.