8. TROUBLESHOOTING

The ranging does not work. The display is transparent.

Check the charge of the battery. Replace it if it is weak.

The ranging mode does not work. The display shows results of the last measurement or is transparent.

Wait for 16 seconds, and press the Action button again.

Compass shows zero at any direction.

Wait for 8 seconds, and press the Action button again. If this does not help, perform compass calibration.

Black dots are visible on LCD.

Liquid Crystal Display may have small black dots, scratches and other blemishes inherited from the manufacturing process. These flaws are strictly regulated by number, area and location and do not degrade the product's measurement capabilities.

Range measurement cannot be obtained.

Make sure that neither your hand nor finger is blocking objective lens, laser emitting lens or receiver lens.

Hold the unit firmly (avoid hand tremor) while pressing the Action button.

Check that the target is within measuring range of the device.