Changing battery

To install a battery:

Slide the battery compartment cover down (Fig. 2)

Install the battery, observing correct polarity

Do not force the battery while placing back inside the compartment.

Close the compartment cover

If the battery does not fit the compartment easily, it means that either polarity was reversed or the battery contacts are jammed.

To remove battery:

Slide the battery compartment cover down (Fig. 2)

Shake the rangefinder gently towards the open end of the battery compartment

Pull out the battery

The unit is fully operational when battery voltage is higher than 6.2V. A ‘LOW BATTERY’ warning is displayed when battery voltage falls below 6.5V.

Ni-MH rechargeable batteries capable to sustain current drain up to 250 mA can be used to power the unit.

Note: Non-magnetic batteries should be used for peak compass performance. If a non-magnetic battery is not used, you may need to calibrate the unit after changing the battery (see Compass calibration below for more details).