Nilfisk-Advance America IVB 3-H, IVB 7-H, IVB 5-H manual Troubleshooting, Fault, Cause, Remedy

Models: IVB 7-H IVB 3-H IVB 5-H

1 19
Download 19 pages 39.67 Kb
Page 16
Image 16
8 Troubleshooting

IVB 3-H IVB 5-H IVB 7-H

english

8 Troubleshooting

 

Fault

 

 

Cause

 

Remedy

‡ Motor does not start

>

Fuse of the mains socket has

Connect mains fuse.

 

 

 

 

blown.

 

 

 

 

 

 

>

Overload

protection switch

• Switch off the vacuum cleaner

 

 

 

 

has tripped.

 

and allow it to cool for approx.

 

 

 

 

 

 

 

5 minutes. If the cleaner can-

 

 

 

 

 

 

 

not be started again, contact

 

 

 

 

 

 

 

the Nilfisk-Advance service

 

 

 

 

 

 

 

department.

 

 

 

> Self-acting

carbon brush is

• Have carbon brushes changed

 

 

 

 

worn.

 

 

by Nilfisk-Advance Service.

 

 

 

 

 

‡ Motor does not run in auto-

>

Power tool is defective or not

Check that the power tool

 

matic mode

 

 

connected properly.

 

works or that the plug is inser-

 

 

 

 

 

 

 

ted correctly.

 

 

 

> The power rating of the elec-

• Note that minimum power ra-

 

 

 

 

trical tool is too low.

 

ting is P>40W

 

 

 

 

 

 

 

The acoustic

warning

>

Suction power selected with

Set suction power in accor-

 

sounds. (Reduced

suction

 

suction power control is too

 

dance with section 4.2.3. „Set-

 

power)

 

 

low.

 

 

ting suction power“.

 

 

 

> Hose diameter is not right for

• Set correct switch position for

 

 

 

 

switch position.

 

hose diameter.

 

 

 

>

Clogged suction hose/nozzle.

Clean suction hose/nozzle

 

 

 

> The safety filter bag is full.

See section 7.2.2 „Replacing

 

 

 

 

 

 

 

filter bag“.

 

 

 

> Filter element is clogged.

• See section 4.5 „Cleaning filter

 

 

 

 

 

 

 

element“ and 7.2.3 „Replacing

 

 

 

 

 

 

 

filter element“.

 

 

 

>

Defective cleaning mecha-

Contact Nilfisk-Advance Serv-

 

 

 

 

nism

 

 

ice

 

 

 

 

 

‡ No suction power during

>

Tank is full. (Float is blocking

Switch off the cleaner. Empty

 

wet cleaning

 

 

the suction opening).

 

the tank.

 

 

 

 

 

 

 

The vacuum cleaner swit-

>

Tank is full.

 

Switch off the cleaner. Empty

 

ches off during wet clea-

 

 

 

 

the tank.

 

ning

 

 

 

 

 

 

 

 

 

 

 

Voltage fluctuations

>

Impedance of power supply is

• Connect the cleaner to another

 

 

 

 

too high.

 

 

socket closer to the fuse box.

 

 

 

 

 

 

 

Voltage fluctuations over 7%

 

 

 

 

 

 

 

should not occur if the impe-

 

 

 

 

 

 

 

dance at the transfer point is

 

 

 

 

 

 

 

0.15 Ω .

 

 

 

 

 

 

 

 

14

Page 16
Image 16
Nilfisk-Advance America IVB 3-H, IVB 7-H, IVB 5-H manual Troubleshooting, Fault, Cause, Remedy