MAINTENANCE
BATTERIES: CONTROL AND RECHARGE
Make a frequent check of the electrolyte level inside every battery cell. The battery compartment is under the operator seat; lift the lid and open the caps of all the battery cells: when necessary fill up the cells with distilled water.
The proper electrolyte level is specified in the Manual for use and maintenance of the battery.
Warning: On the version with petrol engine the battery level check must be done every week.
After filling close all the cell caps and clean the top of the battery from any acid remains.
Warning: the battery acid is corrosive; if it comes in contact with the skin or eyes rinse thoroughly with water and consult a physician.
When necessary proceed with a recharge of the battery according to the following instructions and taking also into account what is specified in the Battery User Manual:
-switch the machine Off and remove the master key.
Warning: before starting the recharge the battery connector must be disconnected from the machine.
-the recharge must be done in a well ventilated area
-open all the cell caps
-connect the battery connector to the battery charger connector
-connect the battery charger cable to the mains (please check that the voltage and frequency of the mains correspond to the data of the charger)
At the end of the recharge disconnect the battery from the charger and fit the battery connector to the machine. Close all the cell caps and clean the top of the battery from any acid remains.
Note: in any case refer to the instructions specified in the Battery Use Manual.
|
19