FILTER CLEANING AND REPLACEMENT
The panel filter requires a regular cleaning.
Lift the lid.
|
Remove the lid of the filter compartment.
Disconnect the electric cable of the
Loosen the two screws with butterfly head on the two sides of the metal frame fixing the panel filter; it is not necessary to remove the screws completely.
Remove the metal frame and take the panel filter out.
Clean the filter shaking, blowing it with compressed air - pressure not higher than 6 bar- from the side where the metal protection net is mounted, to avoid damaging to the paper.
17