SUMMARY OF MAINTENANCE

S31NUK5120(3)2001-04

CONTROLS (petrol version)

 

 

 

Warning: the following interventions must be done with machine in Off condition and master key out. All the periodic maintenance operations must be performed by skilled personnel or by an authorized service centre.

Every maintenance intervention on the petrol engine must be performed in agreement with the engine User Manual.

Note: the battery life will depend on a good periodic maintenance (check of the level of the electrolyte and of battery voltage). Besides it must be taken into account that an unused battery is submitted to a self-discharge phenomenon. In the event that the machine is not used for a long time (e.g. 3 or 4 weeks) it is necessary TO RECHARGE THE BATTERY; infact the battery voltage MUST NEVER drop down below 20 Volt.

 

UPON

TWO

ONE

EVERY

EVERY

EVERY

EVERY

CONTROL

TIMES PER

TIME PER

20

50

100

400

DELIVERY

 

 

WEEK

WEEK

HOURS

HOURS

HOURS

HOURS

 

 

 

 

 

 

 

 

Battery liquid level and voltage

 

 

 

 

 

check

 

 

 

 

 

 

 

 

 

 

 

 

Engine air filter cleaning

 

 

 

 

 

 

Panel filter cleaning

 

 

 

 

 

 

Engine oil level check

1st TIME

 

 

 

 

 

Engine oil replacement

 

 

 

(+)

 

(++)

 

 

 

 

 

1stTIME

 

 

 

 

 

 

 

 

 

Engine RPM check and

 

 

 

 

 

 

adjustment (*)

 

 

 

 

 

 

 

 

 

 

 

 

 

Check the carbon brushes of all

 

 

 

 

 

 

 

electrical motors and replace

 

 

 

 

 

 

them if worn

 

 

 

 

 

 

 

Belt tension

 

 

 

 

 

Brake adjustment

 

 

 

 

 

Filter shaker

 

 

 

 

 

 

Nut and screw tightness

 

 

 

 

 

 

Wear of main brush and side

 

 

 

 

 

 

brushes

 

 

 

 

 

 

 

 

 

 

 

 

 

Sealing of gaskets of filter

 

 

 

 

 

compartment and of flaps

 

 

 

 

 

 

 

 

 

 

 

 

Clean the steering chain and

 

 

 

 

 

 

 

(SR 1200 - SR 5120 only) the

 

 

 

 

 

 

traction wheels chains with gas-

 

 

 

 

 

 

 

 

 

 

 

 

 

oil or a proper solvent.

 

 

 

 

 

 

 

For SR1100: 3200 engine shaft RPM with no function working and battery voltage higher than 27 Volt

For SR 1200: 3300 engine shaft RPM with no function working and battery voltage higher than 27 Volt

(+)20 hours or not more than 1 month (++) 100 hours or not more than 8 months

24

Page 26
Image 26
Nilfisk-Advance America SR 5110 P/B, SR 5120 P/B, SR 1200 P/B, SR 1100 P/B manual Controls petrol version