SUMMARY OF MAINTENANCE

S31NUK5120(3)2001-04

CONTROLS (battery version)

 

 

 

Warning: the following interventions must be done with machine in Off condition and master key out. All the periodic maintenance operations must be performed by skilled personnel or by an authorized service centre.

Note: the battery life will depend on a good periodic maintenance (check of the level of the electrolyte and of battery voltage). Besides it must be taken into account that an unused battery is submitted to a self-discharge phenomenon. In the event that the machine is not used for a long time (e.g. 3 or 4 weeks) it is necessary TO RECHARGE THE BATTERY; in fact the battery voltage MUST NEVER drop down below 20 Volt.

CONTROL

UPON

EVERY

EVERY

EVERY 100

EVERY 400

30

50

DELIVERY

HOURS

HOURS

 

HOURS

HOURS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery liquid level and

 

 

 

 

voltage

 

 

 

OR EVERY TWO

 

 

 

check

 

WEEKS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check the carbon brushes

 

 

 

 

 

of all electrical motors and

 

 

 

 

replace them if worn

 

 

 

 

 

 

 

 

 

 

 

Belt tension

 

 

 

 

 

 

 

 

 

Brake adjustment

 

 

 

 

 

 

 

 

 

Filter shaker

 

 

 

 

 

 

 

 

 

 

Nut and screw tightness

 

 

 

 

 

 

 

 

 

 

Wear of main brush and

 

 

 

 

side brushes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Panel filter cleaning

 

 

 

 

 

 

 

 

 

 

Sealing of gaskets of filter

 

 

 

compartment and of flaps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean the steering chain

 

 

 

 

 

and (SR 1200 - SR 5120

 

 

 

 

 

only) the traction wheels

 

 

 

 

chains with gas-oil or a

 

 

 

 

 

proper solvent.

 

 

 

 

 

 

 

 

 

 

 

23

Page 25
Image 25
Nilfisk-Advance America SR 1200 P/B, SR 5120 P/B, SR 5110 P/B, SR 1100 P/B Summary of Maintenance, Controls battery version