Page 28
Image 28
SAFETY FUNCTIONS AND TROUBLE- SHOOTING

SAFETY FUNCTIONS AND TROUBLE- SHOOTING

The machine is equipped with many safety devices and functions which have been described in the USE paragraphs (both for petrol and electrical versions). For instance the automatic stop of all functions to avoid the deep discharge of the battery has been mentioned; and also the availability of a special red key for the disengagement of the self-breaking function has been notified: this is to be operated when the machine must be pushed in Off condition.

Besides the intervention of other safety functions is notified by means of dedicated safety codes appearing on the display. These safety codes are described in the following table.

S31NUK5120(3)2001-04

TO PUSH

TO DRIVE

SEE SAFETY CODE 333

SAFETY

MACHINE BEHAVIOUR

DESCRIPTION OF THE

POSSIBLE INTERVENTION

CODE

MALFUNCTION

 

 

 

 

 

 

 

Stop of all functions except

 

Recharge the battery according to

205

The battery is empty

the instructions given in the

traction

 

 

Maintenance paragraph

 

 

 

 

 

 

-If the machine run on a long ramp it

 

 

 

could be normal: let the machine

 

 

 

cooling 20 minutes

301

Stop of all functions and traction

Overtemperature of the drive motor

-Check the efficiency of the front

 

 

 

and rear brakes

 

 

 

-Check the rotation of the rear drive

 

 

 

wheels

 

 

 

-Check carbon brushes of traction

 

 

 

motor

302

The machine does not start or, in

Possible problem with traction

-Check connection cables of

the event it was working, will stop

control electronic circuit

traction motor

 

 

 

 

-If the above is OK replace the

 

 

 

power electronic board

 

 

 

-If the ambient temperature is high

 

 

 

let the machine cool down 20

305

The machine functions will stop

High temperature on the electronic

minutes

control circuits (95 °C)

-If the problem will remain call the

 

 

 

 

 

technical service to check the

 

 

 

electrical motors

306

Stop of all functions and traction

High temperature on the electronic

-Make the same checks as per code

control circuits (105 °C)

305

 

 

307

The machine does not start

Wrong start sequence

-Release the accelerator pedal

before turning the key On

 

 

 

 

 

 

-Check the cable connections of the

308

The machine does not start

Damage of the cable of

potentiometer for traction control

potentiometer for traction control

- Check the potentiometer for

 

 

 

 

 

traction control

 

 

-Off status of the red key for the

 

 

 

disabling of the self braking

-Insert the red key and turn it

 

 

function (see the picture on the

333

The machine does not start

clockwise

top page)

 

 

-Check the motor cables

 

 

-Possible trouble of motor kables

 

 

 

 

 

(short circuit or open circuit)

 

800

Display flashing

Main brush worn

-Replace the main brush

E10

Flashing display

Main broom is blocked

Remove the main broom and clean

 

all dirty parts

 

 

 

26

Page 28
Image 28
Nilfisk-Advance America SR 5120 P/B, SR 1200 P/B Safety Functions And Trouble- Shooting, To Push To Drive See Safety Code