NEPTUNE 5 FA

3.3Install Crank handle for high pressure hose reel/cord reel

1.Pull cap of crank in arrow direction.

2.Align tabs on crank with slot in axle.

3.Put crank on axle of high pres- sure hose reel/cord reel.

4.Fix crank by pushing the cap.

3.4Fill up detergent tanks

3.5Fill up tank for Nilfisk- ALTO AntiStone (Anti- Scale)

A

B

1.Fill up detergent tanks (A) and

(B) with prediluted detergent. Capacity see chapter 9.4 Technical Data

1.Fill up Nilfisk-ALTO Anti-Stone (Anti-Scale)/water softener reservoir with the sample bottle provided. Nilfi sk-ALTO AntiStone (Anti-Scale) pre- vents any deposits of scale and acts at the same time as a corrosion inhibitor.

For compatibility reasons, use only the tested Nilfisk-ALTO AntiStone (Anti-Scale) which is available as a six-pack of 1 liter bottles by ordering part number 8466.

3.6Antiscale

The Nilfisk Alto Antiscale dosing

Use the schematic to find

the

system is set by the factory.

right dosage of No Scale/anti

To adjust the water hardness we

stone and water, and add

the

recommend that the inlet water

mixture to the antiscale tank.

is tested accordingly.

 

 

Machine flow L/h

Pump size ml/h

˚dH

˚f

 

˚e

Dosage

 

 

 

 

 

 

 

900

35

0-12

0-21,5

0

- 15

1:1 = 17ml/h

 

 

 

 

 

 

900

35

12-30

21,5 - 53,7

15 - 37,5

Pure = 35ml/h

 

 

 

 

 

 

 

1000

35

0-12

0-21,5

0

- 15

1:1 = 17ml/h

 

 

 

 

 

 

1000

35

12-30

21,5 - 53,7

15 - 37,5

Pure = 35ml/h

 

 

 

 

 

 

 

6

1) Options / model variants

Original instructions

Page 8
Image 8
Nilfisk-ALTO 107400337 C operating instructions Install Crank handle for high pressure hose reel/cord reel, Antiscale