NEPTUNE 5 FA

3.9 Connecting the water supply

NOTE!

See chapter 9.4 Technical Data for required quantity of water and water pressure.

In the case of poor water quality (sand, etc.), it is recommended that an inlet water fi lter be in- stalled.

3.10 Electrical connection

CAUTION!

1.Attach quick connect adapter found with Owners Manual to the water supply hose.

2.Rinse the water supply hose briefly in order to prevent sand an other dirt particles entering into the machine.

3.Attach water supply hose with adapter to inlet quick connec- tor.

4.Open water supply faucet. Water supply hose should be a reinforced hose and have a minimum inside diameter of 3/4" (19 mm).

CAUTION!

When using a cord reel:

400V

400V

230 V / 400 V ?

(220 V / 440 V ?)

Some models have tha ability to be used on either 230 Volt or a 440 Volt power supply. On these models confi rm that the voltage selector switch is in the proper position to match the power supply. Otherwise damage to machines electrical components may occur.

1.Release brake of the cord reel.

2.Unwind the cord completely.

CAUTION!

The cleaner should only be con- nected to a correctly installed electrical supply.

1.Observe safety instructions in chapter 1.

2.Insert the plug into the electri- cal socket.

3.11Antifreeze - before first The machine is flushed with anti-

use

freeze at the factory to protect it

 

against freezin; this mixture (ap-

prox. 5 l) may be captured in a suitable container for reuse.

4 Control / Operation

4.1Connections

4.1.1Connecting the spray lance to the spray gun

A

B

C

NOTE!

Always remove any dirt from the nipple before connecting the spray lance to the spray gun.

1.Pull the blue quick-release grip (A) of the spray gun back- wards.

2.Insert the nipple of the spray lance (B) into the quick-re- lease connection and release it.

3.Pull the spray lance (or other accessory) forwards to check that it is securely attached to the spray gun.

8

1) Options / model variants

Original instructions

Page 10
Image 10
Nilfisk-ALTO 107400337 C Control / Operation, Connecting the water supply, Electrical connection, Use