NEPTUNE 5 FA
7.2.3Checking the pump oil quality
1.Check color of pump oil.
If the oil has a grey or white shade, change the oil (see chapter 7.2.4)
2.Top off oil level with fresh oil if necessary.
Oil type see chapter 9.4 Tech- nical Data.
7.2.4 | Changing the pump oil | 1. | Unscrew the oil drain plug |
|
|
| and drain oil into a suitable |
|
|
| container. |
|
| 2. | Check that the drain plug |
|
|
| gasket is in place and reinstall |
|
|
| drain plug. |
|
| 3. | Fill pump with proper grade |
|
|
| and amount of oil. |
|
|
| Oil grade and capacity see |
|
|
| chapter ‘9.4 Technical Data’. |
7.2.5 Emptying the fuel oil | 1. | Prepare a container which |
tank |
| is capable of containing the |
|
| amount of fuel remaining in |
|
| the tank. |
| 2. | Place drain channel beneath |
|
| the drain plug. |
| 3. | Remove the drain plug and |
|
| drain the fuel into the pre- |
|
| pared container carefully not |
|
| to spill fuel oil. |
| 4. | Check that the drain plug |
|
| gasket is in place and reinstall |
|
| drain plug. |
| 5. | Check tank and plug for |
|
| leaks. |
7.2.6 Flame sensor
1.Remove the sensor and clean with a soft cloth.
2.Confirm that the sensor is correctly seated when rein- stalling.
16 | 1) Options / model variants |
Original instructions