524 1) Options / model variants

NEPTUNE 5 FA

Technical Data
NEPTUNE 5
5-47 FA 5-47 FA 5-50 FA /
5-50 FAX
5-61 FA /
5-61 FAX 5-61 FA 5-61 FAX 5-61 FA 5-50 FAX
Voltage 200 V / 3~ / 50Hz JP
Voltage 200 V / 3~ / 60Hz JP
Voltage 230 V / 1~/ 60Hz US
Voltage 400 V / 3~ / 50Hz EU EU / AU
Voltage 400/230 V / 3~ / 50Hz NO NO
Voltage 220/440 V / 3~ / 60Hz EXPT
Fuse A 20 20 13 16 25 / 16 25 / 16 15 / 25 30
Power rating kW 5.4 5.1 6 / 6.1 7.6 / 7.8 7.6 / 7.4 7.8 / 7.6 7.5 / 7 8
Power consumption A 18.7 16.6 12.2 / 12.3 15.4 / 15.8 25 / 15.6 25 / 15.8 12.3 / 21.3 28
Type of protection IP X5
Working pressure bar
(Mpa) 170(17) 170(17) 190(19) 210(21) 210(21) 210(21) 210(21) 145(15)
Permissible pressure Pmax
bar
(Mpa) 250 250 250 250 250 250 250 220
Volume ow (max) l/h 910 910 960 1110 1110 1110 1110 1040
Volume ow QIEC l/h 850 850 900 1050 1050 1050 1050 1020
High pressure nozzle 0500 0500 0500 0550 0550 0550 0550 0450
Temperature tmax , hotwater °C 90
Temperature tmax , steam °C 150
Max. water inlet temperature °C 40
Max. water inlet pressure bar
(Mpa) 10(1)
Dimensions l x w x h mm 1190 x 702 x 98
Weight kg 160 160 160 / 165 160 / 165 161 166 161 158
Calculated sound pressure at
a distance of 1 m EN 60704-1
LpA +/- KpA *
dB(A) 76
+/- 1,5
76
+/- 1,5
77
+/- 1,5
78
+/- 1,5
78
+/- 1,5
78
+/- 1,5
78
+/- 1,5
80
+/- 1,5
Sound power level LwA MAX
including KwA = 1,5dB * dB(A) 92 92 93 96 96 96 96 94
Vibration ISO 5349 m/s² < 2.5
Recoil forces N 36 35 37/38 48 47 49 47 41
Heating capacity kW 67 67 78 85 85 85 85 78
Fuel tank l35
Detergent tank A / B l 15/10
Oil quantity l 0.75
Oil type BP Energol GR-XP 220
* Noise emission acc. to EN 60335-2-79 ZAA.2.7