8.2 Indication lights on control panel

 

 

 

Indication light

 

Cause

 

Remedy

 

 

 

 

 

 

 

 

 

 

 

fl ashing

>

see FLO

see FLO

 

 

 

 

 

 

 

 

 

 

 

ON

>

Low fuel level

Fill fuel tank

 

 

 

 

 

 

Cold water operation possible

 

 

 

 

 

 

 

 

 

 

 

> Low Nilfi sk-ALTO AntiStone

Fill Nilfisk-ALTO AntiStone (Anti-

 

 

 

 

 

(Anti-Scale) level

 

Scale) tank

 

 

 

fl ashing

>

Service interval: Service due

 

Contact Nilfisk-ALTO Service

 

 

 

 

in 20 hours

 

 

 

 

 

 

 

 

 

 

 

 

ON

>

Service interval expired

 

Contact Nilfisk-ALTO Service

 

 

 

 

 

 

 

 

 

 

 

ON

>

Pump oil low

Fill to proper level

 

 

 

 

 

 

 

8.3 Other Faults

Fault

 

Cause

 

Remedy

 

 

 

not ON

> Power cord not properly

• Check power cord connetction

 

connected to power supply

 

 

 

 

 

 

 

 

 

• Check fuse (see chapter 9.4 Technical

 

 

 

 

Data)

Pressure too low

> High pressure nozzle worn

Replace nozzle

 

 

out

 

 

 

> Pressure regulation set to low

Turn the twist grip on safety control

 

 

pressure

 

 

 

 

block clockwise (+)

 

 

 

 

 

 

 

Machine is running with

> Pump has drawn in air due to

• Close detergent valve. Remove lance

pulsating pressure and

 

detergent tank being empty

 

from gun. Operate spray gun and let

makes knocking noise

 

 

 

machine run until air in pump is gone

 

 

 

 

and the machine is running normally/

 

 

 

 

calm again.

No detergents drawn in

>

Detergent tank empty

Fill detergent tank

 

> Dirt in detergent tank

Clean detergent tank

 

> Suction valve at cleaning

• Remove suction valve and clean or

 

 

agent inlet soiled

 

replace

Burner soots

>

fuel contamination

 

Contact Nilfisk-ALTO Service

 

> Burner sooted or adjustment

 

 

 

 

incorrect

 

 

20