NEPTUNE 5 SB FA

8

Troubleshooting

 

 

8.1 Indications on Display

 

 

 

 

 

 

 

Indication

 

Cause

 

Remedy

on Display

 

 

 

 

 

 

 

 

 

 

 

 

FLF

 

>

Flow sensor fault

 

Contact Nilfi sk-ALTO Service

 

 

Cold water operation possible

 

 

 

 

 

 

 

 

 

 

FLO

 

>

Water supply turned off or inadequate supply

Required volume fl ow and pressure see

 

 

 

 

 

to machine

 

chapter 9.4 Technical Data

 

 

>

Detergent tank empty

Fill detergent tank or set detergent me-

 

 

 

 

 

tering to „OFF“

 

 

>

Pressure regulation on the safety control

Turn the twist grip on safety control block

 

 

 

block set to low water volume

 

to higher water pressure/volume

 

 

>

Machine scaled

 

Contact Nilfi sk-ALTO Service

 

 

 

 

 

 

Fue

 

>

Fuel shortage

Fill fuel tank

 

 

 

Cold water operation possible

 

 

 

 

 

 

 

 

 

 

Hop

 

>

Motor overheated

Turn main switch in position „OFF“, let

 

 

 

 

machine cool down

 

 

 

 

Remove extension cord, if being used.

 

 

 

 

Possible phase failure; have electrical

 

 

 

 

 

connections checked

 

 

 

 

 

 

HOS

 

>

Machine overheated

 

Contact Nilfi sk-ALTO Service

 

 

 

 

 

 

 

 

>

Leakage or inadmissible operating condition

After three times of short-time operation

 

 

 

by short-time operation

 

the machine switches off. To reset: Turn

 

 

 

 

 

main switch to position “OFF“, then start

LEA

 

 

 

 

again. Keep trigger squeezed for longer

 

 

 

 

than 3 seconds. If a leak occurs in the

 

 

 

 

 

hose and gun and causes the machine

 

 

 

 

 

to start and stop briefl y 3 times, then the

 

 

 

 

 

machine will switch off.

 

 

>

Spray gun leaking

Repair Spray gun

 

 

>

High pressure hose, coupling or line system

Replace high-pressure hose, retighten

 

 

 

leaking

 

screw fi ttings

 

 

>

Detergent tank empty

Fill detergent tank or set detergent me-

 

 

 

 

 

tering to „OFF“

 

 

>

Water inlet fi lter dirty

Clean fi lter (see chapter 7.2.1)

 

 

>

High-pressure pump drawing in air

Repair leaks

 

 

 

 

 

 

LHE

 

>

Flame sensor sooted

Clean flame sensor (see chapter

 

 

 

 

7.2.6).

 

 

> Ignition or fuel system failure

 

Contact Nilfi sk-ALTO Service

 

 

 

 

 

Cold water operation possible

 

 

 

 

 

 

LHL

 

>

Burner failure

 

Contact Nilfi sk-ALTO Service

 

 

Cold water operation possible

 

 

 

 

 

 

 

 

 

 

POL

 

>

Pump oil low

Fill to proper level (see chapter 7.2.3)

 

 

 

SEC

 

>

Temperature sensor damaged

 

Contact Nilfi sk-ALTO Service

 

 

Cold water operation possible

 

 

 

 

 

 

 

 

 

 

SEO

 

>

Temperature sensor damaged

 

Contact Nilfisk-ALTO Service

 

 

Cold water operation possible

 

 

 

 

 

 

 

 

 

 

UPC

 

>

Microprocessor failure

 

Contact Nilfisk-ALTO Service

 

 

 

 

 

 

1) Options / model variants

19

Page 21
Image 21
Nilfisk-ALTO 5 SB FA operating instructions Troubleshooting, Indications on Display