Return to Section TOC Return to Master TOC
F-41 TROUBLESHOOTING & REPAIRF-41
TYPICAL AC VOLTAGE WAVEFORM - MACHINE LOADED TO 50 AMPS
AC - TIG MODE
HIGH VOLTAGE/ HIGH FREQUENCY can damage test equipment.
Perform all voltage and waveform checks with high frequency circuit OFF.
Perform High Frequency Disable Procedure.
Return to Section TOC Return to Master TOC
Return to Section TOC Return to Master TOC
Return to Section TOC Return to Master TOC
0V
|
|
|
|
|
|
|
|
20V | 5 ms | ||
AC BALANCE CONTROL IN “AUTO” | |||
This is the typical DC (+) output voltage | |||
waveform generated from a properly | |||
operating machine. Note that each ver- | |||
tical division represents 20 volts and | |||
that each horizontal division represents | |||
5 milliseconds in time. | connected at | ||
NOTE: Scope probes |
machine output terminals: (+) probe to electrode,
SCOPE SETTINGS | |
Volts/Div | 20V/Div. |
Horizontal Sweep | 5 ms/Div. |
Coupling | DC |
Trigger | Internal |