Return to Section TOC Return to Master TOC

F-41TROUBLESHOOTING & REPAIRF-41

TYPICAL AC VOLTAGE WAVEFORM - MACHINE LOADED TO 50 AMPS

AC - TIG MODE

HIGH VOLTAGE/ HIGH FREQUENCY can damage test equipment.

Perform all voltage and waveform checks with high frequency circuit OFF.

Perform High Frequency Disable Procedure.

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

0V

 

 

 

 

 

 

 

 

20V

5 ms

AC BALANCE CONTROL IN “AUTO”

This is the typical DC (+) output voltage

waveform generated from a properly

operating machine. Note that each ver-

tical division represents 20 volts and

that each horizontal division represents

5 milliseconds in time.

connected at

NOTE: Scope probes

machine output terminals: (+) probe to electrode, (-) probe to work.

SCOPE SETTINGS

Volts/Div

20V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

PRECISION TIG 275

Page 87
Image 87
Lincoln Electric SVM162-B 41TROUBLESHOOTING & REPAIRF-41, Typical AC Voltage Waveform Machine Loaded to 50 Amps