TROUBLESHOOTING & REPAIR

 

 

F-15

TROUBLESHOOTING GUIDE

 

 

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

FUNCTION PROBLEMS

 

 

 

 

The meter does not display V (volt)

1. Check that either the advanced

1. Check R1

potentiometer

and

or minimum current.

 

control board or jumper plug is in

associated

leads between

the

 

 

J3 on the control board.

control board and plug J9. See

 

 

 

the Wiring Diagram.

 

NOTE: BEFORE REPLACING A

 

2. The control board may be faulty.

CONTROL BOARD

 

 

 

 

 

 

If an Advanced Control Panel is

 

 

 

 

 

installed, remove it and replace

 

 

 

 

 

the Jumper in connector J-3. If

 

 

 

 

 

the machine functions normally,

 

 

 

 

 

the Advanced Process panel or

 

 

 

 

 

harness is defective.

 

 

 

 

 

 

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.