TROUBLESHOOTING & REPAIR |
|
| ||||
TROUBLESHOOTING GUIDE |
|
| Observe Safety Guidelines | |||
|
| detailed in the beginning of this manual. | ||||
PROBLEMS |
| POSSIBLE AREAS OF | RECOMMENDED |
| ||
(SYMPTOMS) |
| MISADJUSTMENT(S) | COURSE OF ACTION |
| ||
|
| FUNCTION PROBLEMS |
|
|
|
|
The meter does not display V (volt) | 1. Check that either the advanced | 1. Check R1 | potentiometer | and | ||
or minimum current. |
| control board or jumper plug is in | associated | leads between | the | |
|
| J3 on the control board. | control board and plug J9. See | |||
|
|
| the Wiring Diagram. |
| ||
NOTE: BEFORE REPLACING A |
| 2. The control board may be faulty. | ||||
CONTROL BOARD |
|
|
|
|
|
|
If an Advanced Control Panel is |
|
|
|
|
| |
installed, remove it and replace |
|
|
|
|
| |
the Jumper in connector |
|
|
|
|
| |
the machine functions normally, |
|
|
|
|
| |
the Advanced Process panel or |
|
|
|
|
| |
harness is defective. |
|
|
|
|
|
|
Return to Section TOC Return to Master TOC
Return to Section TOC Return to Master TOC
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call