Lincoln Electric SVM162-B service manual Perform the SCR Bridge Test

Models: SVM162-B

1 140
Download 140 pages 825 b
Page 54
Image 54
PRECISION TIG 275

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

F-8

TROUBLESHOOTING & REPAIR

F-8

 

Observe Safety Guidelines

 

 

TROUBLESHOOTING GUIDE

 

detailed in the beginning of this manual.

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

OUTPUT PROBLEMS

 

Perform the SCR Bridge Test.

 

The machine welds at a very high

1. If welding in the TIG mode, the

1.

 

output regardless of the current

remote control device may be

2.

Perform the T1 Transformer

 

control setting.

 

defective.

3.

Test.

 

 

NOTE: BEFORE REPLACING A

 

Check the output current con-

 

 

 

trols for proper

operation.

 

CONTROL BOARD

 

 

Normal resistance

is 10,000

 

If an Advanced Control Panel is

 

4.

ohms. See the Wiring Diagram.

 

installed, remove it and replace

 

Check leads #221 and #222

 

the Jumper in connector J-3. If

 

 

between the output shunt and

 

the machine functions normally,

 

 

the control board.

See the

 

the Advanced Process panel or

 

 

Wiring Diagram.

 

 

harness is defective.

 

 

5. The control board may be faulty

Accessories plugged into the volt 1. Make sure

the accessory plug

1.

The circuit breaker (CB1) may be

receptacle do not work.

and associated leads are in good

2.

faulty.

2.

working condition.

Check the receptacle and asso-

Make certain the correct input

 

ciated leads for loose or faulty

 

voltage is being applied to the

3.

connections.

 

machine.

(The reconnect lead

Perform the T1 Transformer

3.

must be in the correct position.)

 

Test.

The circuit breaker CB1 may be

 

 

4.

tripped. Reset if necessary.

 

 

Only the top part of the recepta-

 

 

 

cle is electronically “Hot” all of

 

 

 

the time.

 

 

 

Return to Section TOC Return to Master TOC

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.

Page 54
Image 54
Lincoln Electric SVM162-B service manual Perform the SCR Bridge Test